Infrared Catalytic Gas Brooder Operating Instruction
Pls read follow instruction carefully before use this product.
Manual Type Brooder operating steps
THD2606,THD6806,THD5606 these models are manual type gas brooder.
Gas type:LPG,Nature gas,Biogas
Automatic type Operating Steps
Notice
FAQ
1. Pls keep the gas inlet pipe side downward sloping when installation the brooder(as shown above) to prevent overheating.
2. It’s normal phenomenon there is blue flame at beginning, after several minutes will disappear.
3. If the blue flame always stay on ceramic plate, pls check whether the pressure too low; If yes, pls adjust the booster pump.
4. If there is a big red flame, the reason maybe is:
a. the pressure is too high. Pls adjust the pressure reducing valve to required pressure.
b. oxygen lack. Pls keep indoor air circulation when infrared gas brooder working.
c. ceramic plate is broken; Pls change the broken ceramic plate.
d. gas purity difference. Each country gas purity is different, maybe will cause big fire, pls match suitable nozzle.
5. If it doesn't heat equal, pls check whether the feather block at filter net. 。
6. This product is flameless, only see the red heating surface no flame in normal working.
7. Pls check up and clean the complete system parts termly.